Calibration Instruments
- Test Standard Universal Test Standard
Universal test standard for simulation of many sensor signals
- Strain Gauge Calibrator IEEE 488 Strain Gauge Calibrator
Calibration instruments for strain gauge measuring amplifiers IEEE-488
- Strain Gauge Calibrator Manual Strain Gauge Calibrator
Manual strain gauge calibrator
Test Standard
Simulation of Process Quantities in Automotive and Mechanical Engineering Applications
- Test instrument for simulation of sensors such as strain gauges (full and half-bridge), potentiometers, thermocouples (type K and J, or L), Pt100, current sensors, voltage sensors and tachometer generators
- Input of transducer values directly as physical parameters. Calibration and nominal values are calculated.
- Easy operation with help of a clear-cut flexible multilayer keyboard
- Transducer values are displayed with high-contrast LCD
- Accuracy 0.1%
- Mobile and flexible use with battery or mains operation
- Various connector terminals for different process values
- Can be adapted to customer-specific requirements
Detailed information can be found in our PDF file
Test Standard for Simulation of Process Quantities in Engineering Applications
Hanna Instruments HI 7004M 4.01 pH Buffer Solution
Test Standard for Simulation of Process Quantities in Engineering Applications
Hanna Instruments HI 7004M 4.01 pH Buffer Solution
IEEE488 Calibration System for Strain Gauge Measuring Amplifiers
Simulation of strain gauge sensors allows automatic testing of strain gauge measuring amplifiers
- Computer controllable via IEEE-488 interface
- plus manual operation with keys
- Single channel or 12 (resp. 24) channel version
- Bridge resistance options: 120, 350 and 1,000 ohms
- Customer-specific bridge resistances and bridge resistance combinations in a single instrument on request (2 resistances combination see above picture)
- Strain gauge resonance settings from 0 - 250 mV/V (0-500 ‰) in 20 steps
- Connection via 7-pin LEMO or Amphenol plug, resp. 7 individual banana plugs with sensing leads for sensor supply current, or custom-designed
- Small, manually operated hand-held devices with strain gauge resonance settings from 0 - 50 mV/V (0-100 ‰) are also available
Detailed information can be found in our PDF file
IEEE488 Calibration System for Strain Gauge Measuring Amplifiers
IEEE488 Calibration System for Strain Gauge Measuring Amplifiers
Manual Strain Gauge Calibrator
Simulation of strain gauge sensors for calibration of amplifiers
- 1-channel or 2-channel version with two simulated bridges available
- Bridge resistance options: 120, 350 and 1,000 ohms
- Customer-specific bridge resistances and bridge resistance combinations in a single instrument on request
- Strain gauge resonance settings from 0 - 50 mV/V (0-100 ‰) in 10 steps
- Connection via 7-pin LEMO or Amphenol plug, resp. 7 individual banana plugs with sensing leads for sensor supply current, or custom-designed
Wonderful blog & good post.Its really helpful for me, awaiting for more new post. Keep Blogging!
ReplyDelete