The Operation of Synchronous Induction Motor

Synchronous Induction Motors


There are three types of motors that can start and run as induction motors yet can lock into the supply frequency and run as synchronous motors as well. They are (1) the wound-rotor motor with dc exciter; (2) the permanent-magnet (PM) synchronous motor; (3) the reluctancesynchronous motor. The latter two types are used today primarily with adjustable-frequency inverter power supplies. In Europe, wound-rotor induction motors have often been provided with low-voltage dc exciters that supply direct current to the rotor, making them operate as synchronous machines. With secondary rheostats for starting, such a motor gives the low starting current and high torque of the wound-rotor induction motor and an improved power factor under load. Several different forms of these synchronous induction motors have been proposed, but they have not shown any net advantage over usual salientpole synchronous or induction machines and are very seldom used in the United States. The PM synchronous motor is shown in Fig. 8.2a.

 The SquirrelCage

The construction is the same as that of an ordinary squirrel-cage motor (either single or polyphase), except that the depth of rotor core below the squirrel-cage bars is very shallow, just enough to carry the rotor flux under locked-rotor conditions. Inside this shallow rotor core is placed a permanent magnet, fully magnetized. The rotor core serves as a keeper, so that the rotor is not demagnetized by removing it from the stator. In starting, the rotor flux is confined to the laminated core. As the speed rises, the rotor frequency decreases and the rotor flux builds up, creating a pulsating torque with the field of the magnet, as when a synchronous
motor is being synchronized after the dc field has been applied. As the motor approaches full speed, therefore, the ac impressed field locks into step with the field of the magnet and the machine runs as a synchronous motor. The absence of rotor I2R loss, the synchronous speed operation, and the high efficiency and power factor make the motor very attractive
for special applications, such as high-frequency spinning motors. When many such motors are supplied from a high-frequency source, the Kva such subsynchronous motors, and their use is therefore limited to very small sizes, such as may be used in small timer or instrument motors.

requirements are reduced to perhaps 50% of those needed for usual induction motor types, with consequent large savings.



If the rotor surface of a P-pole squirrel-cage motor is cut away at symmetrically spaced points, forming P salient poles, the motor will accelerate to full speed as an induction motor and then lock into step and operate as a synchronous motor. The synchronizing torque is due to the change in reluctance and, therefore, in stored magnetic energy, when the air-gap flux moves from the low- into the high-reluctance region. Such motors are often used in small-horsepower sizes, when synchronous operation is required, but they have inherently low pull-out torque and low power factor, and also poor efficiency, and therefore require larger frames than the same horsepower induction motor. The PM synchronous motor has superior performance in every way, except possibly cost. A cross section of the reluctance-synchronous motor is shown in Fig. 8.2b.
These motors are available up to about 5 hp.


If the number of rotor salients is nP, instead of P, and if the P-pole motor winding is arranged to also produce a field of (n+1)P or (n-1)P poles, the motor may lock into step at a subsynchronous speed and run as a subsynchronous motor. For the P-pole fundamental mmf, acting on the varying rotor permeance, will create (n+1)P and (n-1)P pole fields from this base, and these will lock into step with the independently produced (n-1)P- or (n+1)P-pole field, when the rotor speed is such as to make the two harmonic fields turn at the same speed in the same direction.

It is difficult to provide much torque in such subsynchronous motors, and their use is therefore limited to very small sizes, such as may be used in small timer or instrument motors.


















The synchronous induction motor

                               

No comments:

Post a Comment

Labels

PROJECTS 8086 PIN CONFIGURATION 80X86 PROCESSORS TRANSDUCERS 8086 – ARCHITECTURE Hall-Effect Transducers INTEL 8085 OPTICAL MATERIALS BIPOLAR TRANSISTORS INTEL 8255 Optoelectronic Devices Thermistors thevenin's theorem MAXIMUM MODE CONFIGURATION OF 8086 SYSTEM ASSEMBLY LANGUAGE PROGRAMME OF 80X86 PROCESSORS POWER PLANT ENGINEERING PRIME MOVERS 8279 with 8085 MINIMUM MODE CONFIGURATION OF 8086 SYSTEM MISCELLANEOUS DEVICES MODERN ENGINEERING MATERIALS 8085 Processor- Q and A-1 BASIC CONCEPTS OF FLUID MECHANICS OSCILLATORS 8085 Processor- Q and A-2 Features of 8086 PUMPS AND TURBINES 8031/8051 MICROCONTROLLER Chemfet Transducers DIODES FIRST LAW OF THERMODYNAMICS METHOD OF STATEMENTS 8279 with 8086 HIGH VOLTAGE ENGINEERING OVERVOLATGES AND INSULATION COORDINATION Thermocouples 8251A to 8086 ARCHITECTURE OF 8031/8051 Angle-Beam Transducers DATA TRANSFER INSTRUCTIONS IN 8051/8031 INSTRUCTION SET FOR 8051/8031 INTEL 8279 KEYBOARD AND DISPLAY INTERFACES USING 8279 LOGICAL INSTRUCTIONS FOR 8051/8031 Photonic Transducers TECHNOLOGICAL TIPS THREE POINT STARTER 8257 with 8085 ARITHMETIC INSTRUCTIONS IN 8051/8031 LIGHTNING PHENOMENA Photoelectric Detectors Physical Strain Gage Transducers 8259 PROCESSOR APPLICATIONS OF HALL EFFECT BRANCHING INSTRUCTIONS FOR 8051/8031 CPU OF 8031/8051 Capacitive Transducers DECODER Electromagnetic Transducer Hall voltage INTEL 8051 MICROCONTROLLER INTEL 8251A Insulation Resistance Test PINS AND SIGNALS OF 8031/8051 Physical Transducers Resistive Transducer STARTERS Thermocouple Vacuum Gages USART-INTEL 8251A APPLICATIONs OF 8085 MICROPROCESSOR CAPACITANCE Data Transfer Instructions In 8086 Processors EARTH FAULT RELAY ELECTRIC MOTORS ELECTRICAL AND ELECTRONIC INSTRUMENTS ELECTRICAL BREAKDOWN IN GASES FIELD EFFECT TRANSISTOR (FET) INTEL 8257 IONIZATION AND DECAY PROCESSES Inductive Transducers Microprocessor and Microcontroller OVER CURRENT RELAY OVER CURRENT RELAY TESTING METHODS PhotoConductive Detectors PhotoVoltaic Detectors Registers Of 8051/8031 Microcontroller Testing Methods ADC INTERFACE AMPLIFIERS APPLICATIONS OF 8259 EARTH ELECTRODE RESISTANCE MEASUREMENT TESTING METHODS EARTH FAULT RELAY TESTING METHODS Electricity Ferrodynamic Wattmeter Fiber-Optic Transducers IC TESTER IC TESTER part-2 INTERRUPTS Intravascular imaging transducer LIGHTNING ARRESTERS MEASUREMENT SYSTEM Mechanical imaging transducers Mesh Current-2 Millman's Theorem NEGATIVE FEEDBACK Norton's Polarity Test Potentiometric transducers Ratio Test SERIAL DATA COMMUNICATION SFR OF 8051/8031 SOLIDS AND LIQUIDS Speed Control System 8085 Stepper Motor Control System Winding Resistance Test 20 MVA 6-digits 6-digits 7-segment LEDs 7-segment A-to-D A/D ADC ADVANTAGES OF CORONA ALTERNATOR BY POTIER & ASA METHOD ANALOG TO DIGITAL CONVERTER AUXILIARY TRANSFORMER AUXILIARY TRANSFORMER TESTING AUXILIARY TRANSFORMER TESTING METHODS Analog Devices A–D BERNOULLI’S PRINCIPLE BUS BAR BUS BAR TESTING Basic measuring circuits Bernoulli's Equation Bit Manipulation Instruction Buchholz relay test CORONA POWER LOSS CURRENT TRANSFORMER CURRENT TRANSFORMER TESTING Contact resistance test Current to voltage converter DAC INTERFACE DESCRIBE MULTIPLY-EXCITED Digital Storage Oscilloscope Display Driver Circuit E PROMER ELPLUS NT-111 EPROM AND STATIC RAM EXCITED MAGNETIC FIELD Electrical Machines II- Exp NO.1 Energy Meters FACTORS AFFECTING CORONA FLIP FLOPS Fluid Dynamics and Bernoulli's Equation Fluorescence Chemical Transducers Foil Strain Gages HALL EFFECT HIGH VOLTAGE ENGG HV test HYSTERESIS MOTOR Hall co-efficient Hall voltage and Hall Co-efficient High Voltage Insulator Coating Hot-wire anemometer How to Read a Capacitor? IC TESTER part-1 INSTRUMENT TRANSFORMERS Importance of Hall Effect Insulation resistance check Insulator Coating Knee point Test LEDs LEDs Display Driver LEDs Display Driver Circuit LM35 LOGIC CONTROLLER LPT LPT PORT LPT PORT EXPANDER LPT PORT LPT PORT EXTENDER Life Gone? MAGNETIC FIELD MAGNETIC FIELD SYSTEMS METHOD OF STATEMENT FOR TRANSFORMER STABILITY TEST METHODS OF REDUCING CORONA EFFECT MULTIPLY-EXCITED MULTIPLY-EXCITED MAGNETIC FIELD SYSTEMS Mesh Current Mesh Current-1 Moving Iron Instruments Multiplexing Network Theorems Node Voltage Method On-No Load And On Load Condition PLC PORT EXTENDER POTIER & ASA METHOD POWER TRANSFORMER POWER TRANSFORMER TESTING POWER TRANSFORMER TESTING METHODS PROGRAMMABLE LOGIC PROGRAMMABLE LOGIC CONTROLLER Parallel Port EXPANDER Paschen's law Piezoelectric Wave-Propagation Transducers Potential Transformer RADIO INTERFERENCE RECTIFIERS REGULATION OF ALTERNATOR REGULATION OF THREE PHASE ALTERNATOR Read a Capacitor SINGLY-EXCITED SOLIDS AND LIQUIDS Classical gas laws Secondary effects Semiconductor strain gages Speaker Driver Strain Gages Streamer theory Superposition Superposition theorem Swinburne’s Test TMOD TRANSFORMER TESTING METHODS Tape Recorder Three-Phase Wattmeter Transformer Tap Changer Transformer Testing Vector group test Virus Activity Voltage Insulator Coating Voltage To Frequency Converter Voltage to current converter What is analog-to-digital conversion Windows work for Nokia capacitor labels excitation current test magnetic balance voltage to frequency converter wiki electronic frequency converter testing voltage with a multimeter 50 hz voltages voltmeter